Fuel
Observed volume = from the sounding or ullage and the tank table, after trim and list correction.
Result
0.000t
- Observed volume 0.000 m³
- Volume at 15 °C 0.000 m³
- Weight factor (in air) –
- Difference from BDN –
Guide only. Always check against your ship's manuals, tank tables, the BDN and your company procedures.
How it is worked out
- Each tank's observed volume is corrected to 15 °C with the volume correction factor (VCF) from ASTM Table 54B for fuel oils.
- Volume at 15 °C × (density at 15 °C − 1.1) ÷ 1000 gives tonnes in air, the figure used on the BDN.
- The total is compared with the BDN. A shortfall above about 0.5 % is worth a note of protest.
Formula
ΔT = T − 15
α = 186.9696 / ρ15² + 0.4862 / ρ15
VCF = exp(−α·ΔT·(1 + 0.8·α·ΔT))
V15 = Vobs × VCF
t = V15 × (ρ15 − 1.1) / 1000
ρ15 in kg/m³. Table 54B fuel-oil constants apply to densities of about 839 to 1075 kg/m³.
Learn the main engine properly
Book 1: The Main Engine — how it works, what goes wrong and how to fix it, with exam questions and a video lesson for every chapter.